S-2.1, r. 14 - Regulation respecting occupational health and safety in mines

Full text
426. Subject to section 418.3, detonators and microconnectors shall not be stored or kept within 8 m (26.2 ft) of other types of explosives despite subparagraph f of subparagraph 1 of the first paragraph of section 424 or brought into a magazine or place where such explosives are stored.
The distance of 8 m (26.2 ft.) must be measured along the longitudinal axis of the drift. That requirement only applies to magazines built on or after 11 July 2013.
O.C. 213-93, s. 426; O.C. 42-2004, s. 21; O.C. 621-2013, s. 10.
426. Subject to section 418.3, detonators and microconnectors shall not be stored or kept within 8 m (26.2 ft) of other types of explosives or brought into a magazine or place where such explosives are stored.
O.C. 213-93, s. 426; O.C. 42-2004, s. 21.